Opened 15 years ago
Closed 9 years ago
#61 closed enhancement (fixed)
Coordonnees en lambert93
Reported by: | david | Owned by: | cedric |
---|---|---|---|
Priority: | minor | Milestone: | 41 paramètrage saisie JAVA0.4 |
Component: | database | Version: | 0.4 |
Keywords: | Cc: |
Description
Les coordonnées sont-elles bien à renseigner en Lambert II étendu? La nouvelle norme étant Lambert 93 (système de coordonnées demandé par l'ONEMA pour la convention Bancarisation), peut-on déjà l'intégrer (contraintes à revoir) ?
Voir aussi ticket:#49
Change History (8)
comment:1 Changed 15 years ago by cedric
comment:2 Changed 15 years ago by cedric
- Status changed from new to accepted
comment:3 Changed 13 years ago by cedric
- Milestone changed from debugv0.3 to Release v0.4
- Version changed from 0.3 to 0.4
comment:4 Changed 13 years ago by cedric
- Milestone changed from Release v0.4 to release 0.5
- Version changed from 0.4 to 0.5
comment:5 in reply to: ↑ description Changed 9 years ago by cedric
Replying to david:
Les coordonnées sont-elles bien à renseigner en Lambert II étendu? La nouvelle norme étant Lambert 93 (système de coordonnées demandé par l'ONEMA pour la convention Bancarisation), peut-on déjà l'intégrer (contraintes à revoir) ?
Voir aussi ticket:#49
Demande de sophie également
comment:6 Changed 9 years ago by cedric
- Milestone changed from 5 Release stacomiR_0.5 to 41 paramètrage saisie JAVA0.4
- Version changed from 0.5 to 0.4
comment:7 Changed 9 years ago by cedric
alter table mrm.t_station_sta DROP CONSTRAINT c_ck_sta_coordonnee_x;
alter table mrm.t_station_sta ADD CONSTRAINT c_ck_sta_coordonnee_x
CHECK (sta_coordonnee_x >= -40000 AND sta_coordonnee_x < 1400000);
alter table mrm.t_station_sta DROP CONSTRAINT c_ck_sta_coordonnee_y;
alter table mrm.t_station_sta ADD CONSTRAINT c_ck_sta_coordonnee_y
CHECK (sta_coordonnee_y >= 1200000 AND sta_coordonnee_y < 3400000);
alter table mrm.t_ouvrage_ouv DROP CONSTRAINT c_ck_ouv_coordonnee_x;
alter table mrm.t_ouvrage_ouv ADD CONSTRAINT c_ck_ouv_coordonnee_x
CHECK (ouv_coordonnee_x >= -40000 AND ouv_coordonnee_x < 1400000);
alter table mrm.t_ouvrage_ouv DROP CONSTRAINT c_ck_ouv_coordonnee_y;
alter table mrm.t_ouvrage_ouv ADD CONSTRAINT c_ck_ouv_coordonnee_y
CHECK (ouv_coordonnee_y >= 1200000 AND ouv_coordonnee_y < 3400000);
comment:8 Changed 9 years ago by cedric
- Resolution set to fixed
- Status changed from accepted to closed
Question : quelles sont les coordonnées (bounding box) pour la France pour mettre les limites